Cod.100 - Manual water mixing system on platform |
|
|
- Diameters from 1" to 3"
- Feeding from 80 to 700 lt/min
- Quantity check on dial meter
- Temperature check on dial thermometer
EMPLOYMENT:
The manual water unit has a correct employment every time it's necessary to feed water to the drums or paddles of tannery checking manually the temperature and the quantity.
GENERAL CHARACTERISTICS:
- Assembling in stainless steel AISI 304
- Pressure: from 0,1 to 5 bar
- Dial thermometer: probe in AISI 316 scale 0°-60°C
- Dial counter: scale 0-5000 lt. with pointer zeroise
FUNCTIONING DESCRIPTION:
- Put the pointer of the counter to 0
- Put the lever of the water mixing unit in one of the reference notches remembering that:
1. position 0 = all cold water
2. position 10 = all hot water
3. intermediate position = mixed water
- Open the 2 general valves and check the value of the temperature on the thermometer and correct it as you like, bearing in mind that putting the lever towards the high numbers, the temperature of the water will increase and vice versa.
- At the reaching of desired litres close the 2 general valves
MANUAL WATER MIXING UNITS STANDARD:
Mixer Diameter
|
delivery 2 bar
|
dimension
(vertical)
A
|
dimension
(vertical/horizzontal)
B C
|
hydraulic connections
|
1"
|
80
|
1100
|
680
|
420
|
pipe uniun
|
1 1/2"
|
200
|
1190
|
700
|
490
|
pipe uniun
|
2"
|
350
|
1280
|
550
|
730
|
pipe uniun
|
2 1/2"
|
500
|
1430
|
580
|
840
|
flange
|
3"
|
700
|
1550
|
640
|
910
|
flange
|
|